Wildfire Sprinkler System Simulator
Build a rooftop and ground sprinkler layout, compare hose sizes, account for distance and elevation, and identify pumps that can meet the calculated flow and pressure.
Structure Protection System Simulator
Enter your pump or water source, available flow and pressure, hose layout, elevation, rooftop Water Wingers and ground sprinklers. Results update instantly to compare 3/4 in. and 1-1/2 in. main hose layouts. The 5/8 in. option is reserved for short rooftop branch hose.
1. Where does your water come from?
Start here. The property diagram is empty until you choose a source.
2. Measure the hose route
Measure from the pump or water source to the first point at the house. Then choose a closed loop or a straight dead-end run.
4. Adjust the suggested sprinklers
Tap a product picture, then use the simple number boxes below to say how many you want to run.
5. Choose the hose
6. Add branch fittings
Choose how the main hose connects to sprinkler branches.
Selected pumpwith 5/8 in. closed loop
Flow and pressure estimates use the selected pump curve.
Calculating…
Selected pumpwith 3/4 in. closed loop
Flow and pressure estimates use the selected pump curve.
Calculating…
Selected pumpwith 1-1/2 in. closed loop
Flow and pressure estimates use the selected pump curve.
Calculating…
Planning estimate—not an engineered design. Water Winger demand and throw radius are calculated from the Rain Bird 30H/30WH nozzle chart. The stock 3/16 in. main with 3/32 in. spreader uses 9.0 GPM at 50 PSI. Removing the spreader and installing the included plug reduces charted flow to 7.2 GPM at 50 PSI. Ground choices are: small at 4 GPM with 39 ft throw, 1/2 in. Rain Bird at 5 GPM with 41 ft throw, large 3/4 in. Rain Bird, and the 31 in. tall heavy-duty Rain Bird using the selected Rain Bird main and spreader nozzles. Values are at 50 PSI. The simulator uses manufacturer pump points, USDA hose-friction values and a conservative closed-loop calculation. Pump modes assume a 1-1/2 in. supply line; Home water supply mode uses a 3/4 in. line and the user-entered flowing PSI and available US GPM. Closed-loop mode splits flow in both directions; dead-end mode sends full flow through the full run. Demand is assumed equal among like sprinklers. Actual performance changes with fittings, suction lift, hose condition, nozzle choice and pump condition. Always flow-test the installed system.
Use the results as a planning estimate
Confirm manufacturer specifications, flow-test the installed system and maintain a practical safety margin. Actual results vary with suction lift, fittings, hose condition, water level, nozzle choice and pump condition.